Abstract
张旭,杨敏之,孔祥朋,等.Legion工具在Genesis Ⅱ膝关节假体置换术中的应用.骨科,2019,10(6): 499-503.
Legion工具在Genesis Ⅱ膝关节假体置换术中的应用
Application of Legion tools in the total knee arthroplasty with Genesis Ⅱ prosthesis
投稿时间:2019-06-08  
DOI:10.3969/j.issn.1674-8573.2019.06.003
CN KeyWords: 全膝关节置换术  Legion工具  Genesis Ⅱ假体
EN KeyWords: Total knee arthroplasty  Legion tool  Genesis Ⅱ prosthesis
Fund Project:北京市自然科学基金-海淀原始创新联合基金(HQ1804)
作者单位E-mail
张旭 中国人民解放军总医院第一医学中心北京 100853湖南省岳阳市二人民医院湖南岳阳 414000  
杨敏之 中国人民解放军总医院第一医学中心北京 100853南开大学医学院天津 300071  
孔祥朋 中国人民解放军总医院第一医学中心北京 100853  
柴伟 中国人民解放军总医院第一医学中心北京 100853 chaiwei301@163.com 
View Counts: 6006
PDF Download Counts: 5770
CN Abstract:
      目的 探讨在初次人工全膝关节置换术(total knee arthroplasty, TKA)中应用Legion工具完成Genesis Ⅱ膝关节假体置换术的可行性及临床意义。方法 将中国人民解放军总医院第一医学中心收治的60例单侧内翻型初次TKA病人按随机数字表法分成Legion工具组及Genesis工具组,所有病人均采用Genesis Ⅱ假体,分别采用对应的工具为两组病人完成手术。对病人术前及术后的美国膝关节协会评分(Knee Society Scores, KSS)、最大屈曲角度、术后人工关节被遗忘指数(Forgotten Joint Scores, FJS)及影像学指标进行对比分析。结果 两组病人均获得1年随访,未出现切口相关并发症;术后3个月Legion工具组KSS临床评分及功能评分均高于Genesis工具组[(81.55±4.81)分 vs. (79.05±4.10)分,t=2.165,P=0.035;(84.89±4.60)分 vs. (81.33±5.14)分,t=2.820,P=0.007)],术后12个月两组KSS评分的差异无统计学意义;术后12个月Legion工具组FJS评分优于Genesis工具组[(94.03±6.50)分 vs. (89.62±6.10)分,t=2.706,P=0.009)],病人膝关节最大屈曲角度较Genesis工具组大(123.48°±7.63° vs. 108.19°±9.12°,t=2.436,P=0.018)。结论 使用Legion工具行Genesis Ⅱ置换术,可以发挥其简单、精准、微创、个性化的特点,获得更好的临床疗效。
EN Abstract:
      Objective To investigate the feasibility and clinical significance of Genesis Ⅱ primary total knee arthroplasty with the tools of Legion knee system. Methods Sixty patients with varus knee who underwent unilateral Genesis Ⅱ primary total knee arthroplasty in Chinese PLA General Hospital were divided into two groups randomly: the Legion Tool group was given the tools of Legion knee system, and the Genesis Tool group was subjected to the tools of Genesis Ⅱ knee system. The Knee Society Scores (KSS) and maximum flexion degrees before and after surgery, Forgotten Joint Scores (FJS) and X-ray images after surgery between two groups were compared. Results All patients were followed up for one year without any incision-related complications. The clinical scores and functional scores of the KSS in the Legion tool group were significantly higher than those in the Genesis tool group at 3rd month post-surgery (81.55±4.81 vs. 79.05±4.10, t=2.165, P=0.035; 84.89±4.60 vs. 81.33±5.14, t=2.820, P=0.007). There was no significant difference in the KSS scores between the two groups at 12th month post-surgery. Both the FJS scores (94.03±6.50 vs. 89.62±6.10, t=2.706, P=0.009) and the maximum flexion degrees of the knee joint (123.48°±7.63° vs. 108.19°±9.12°, t=2.436, P=0.018) in the Legion tool group was superior to those in the Genesis tool group. Conclusion Genesis Ⅱ primary total knee arthroplasty with the tools of Legion knee system has the advantage of simplicity, precision, minimal invasion and individuation, as well as better clinical outcomes.